Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Fisioter. Mov. (Online) ; 36: e36109, 2023. tab
Artigo em Inglês | LILACS | ID: biblio-1430328

RESUMO

Abstract Introduction: The increasing insertion of women into the labor market has created a need to adapt handbags, with different sizes and weights, which consequently can overload the musculoskeletal system. Objective: To evaluate the effect of using a unilateral bag on plantar pressures and static balance in women. Methods: Cross-sectional study, carried out in Fortaleza in 2018. 258 women aged between 18 and 59 years who used a unilateral bag participated in this study. Two questionnaires were applied, targeting sociodemographic variables, life habits, characteristics of bag use and level of physical activity. Height, scapular symmetry, body and bag mass were also measured. A baropodometer was used to assess plantar pressure and static balance with and without the unilateral bag. Independent and paired t-tests were applied to verify the influence of the bag on the variables of interest, using the SPSS Statistics program (version 23.0). Results: On the side where the bag was carried, an increase in lateral mass distribution (LMD), foot pressure and surface area, and a decrease in the distance from barycenter (p < 0.05) were observed. On the opposite side, a decrease in LMD and an increase in barycenter were detected (p < 0.05). In static balance, no differences were observed in the anteroposterior and side-to-side oscillations with bag placement (p > 0.05). Conclusion: The unilateral bag causes alterations in plantar pressures and ipsilateral barycenter alongside the use of the bag, being a risk factor or aggravation for dysfunctions of the musculoskeletal system and for the occurrence of pain.


Resumo Introdução: A crescente inserção das mulheres no mercado de trabalho ocasionou uma necessidade de adaptação das bolsas, com tamanhos e pesos diferentes, que por consequência podem sobrecarregar o sistema musculoesquelético. Objetivo: Avaliar o efeito do uso da bolsa unilateral nas pressões plantares e no equilí-brio estático em mulheres. Métodos: Estudo transversal, realizado na cidade de Fortaleza em 2018. Participaram 258 mulheres com idade entre 18 e 59 anos e que usavam bolsa unilateral. Aplicaram-se dois questionários visando as variáveis sociodemográficas, hábitos de vida, características do uso da bolsa e nível de atividade física. Foram mensuradas estatura, simetria escapular, massa corporal e da bolsa. Utilizou-se baropodômetro para a avaliação das pressões plantares e equilíbrio estático com e sem a bolsa unilateral. Aplicaram-se testes t de amostras independentes e pareado para verificar a influência da bolsa nas variáveis de interesse, pelo programa SPSS Statistics (versão 23.0). Resultados: No lado que a bolsa era carregada foram observados aumento da distribuição de massa lateral (DML), da pressão do pé e da área de superfície e diminuição da distância do baricentro (p < 0,05). No lado oposto foram detectados diminuição da DML e aumento do baricentro (p < 0,05). No equilíbrio estático, não foram verificadas diferenças nas oscilações ântero-posterior e látero-lateral com a colocação da bolsa (p > 0,05). Conclusão: A bolsa unilateral causa alterações nas pressões plantares e no baricentro homolaterais no lado do uso da bolsa, sendo um fator de risco ou agravamento para as disfunções do sistema musculoesquelético e para a ocorrência de dor.


Assuntos
Humanos , Feminino , Adolescente , Adulto , Pessoa de Meia-Idade , Mulheres , Fatores de Risco , Equilíbrio Postural , Marcha , Estudos Transversais , Hábitos
2.
Acta ortop. bras ; 26(6): 397-400, Nov.-Dec. 2018. graf
Artigo em Inglês | LILACS | ID: biblio-973584

RESUMO

ABSTRACT Objectives: To compare the accuracy of insertion of pedicle screws into the thoracic spine using fluoroscopic guidance or computer-assisted navigation techniques. Methods: Eight cadaveric thoracic spines were divided into two groups: the fluoroscopy group, in which pedicle screws were inserted with the guidance of a C-arm device, and the navigation group, in which insertion of the screws was monitored using computer-assisted navigation equipment. All procedures were performed by the same spinal surgeon. The rate of pedicle breach was compared between the two groups. Results: There was one intra-canal perforation in each group. Both perforations were medial in direction, and the breaches were 2 to 4 mm deep. There were no statistically significant differences in breach rate between the two groups. Conclusions: The accuracy of insertion of pedicle screws in the thoracic spine using computer-assisted navigation is equivalent to that achieved using fluoroscopic guidance. Computer-assisted navigation improves the safety of the surgical team during the procedure due to the absence of exposure to radiation. Therefore, there is a need for future randomized controlled trials to be conducted in the clinical setting to evaluate other outcomes, including duration of surgery and blood loss during the procedure. Level of evidence IV.


RESUMO Objetivos: Comparar a acurácia da inserção de parafusos pediculares na coluna torácica, utilizando fluoroscopia ou técnicas de navegação assistidas por computador. Métodos: Estudo experimental com cadáveres. Oito colunas torácicas proveniente de cadáveres foram divididas em dois grupos: no grupo Fluoroscopia os parafusos pediculares foram inseridos com orientação de um aparelho tipo C-arm, e no grupo Navegação o monitoramento foi feito com um equipamento de assistência por computador. Todos os procedimentos foram feitos pelo mesmo cirurgião de coluna. A taxa de violação do canal foi comparada entre os grupos. Resultados: Houve uma perfuração de canal em cada grupo, ambas mediais, com 2-4 mm de profundidade. Não houve diferenças significativas entre os dois grupos em termos de taxa de perfuração do canal. Conclusão: A acurácia na inserção de parafusos pediculares na coluna torácica é igual comparando-se a navegação assistida por computador e o método de monitoramento por fluoroscopia. Como a segurança do procedimento para a equipe cirúrgica é maior com o método da navegação, devido à ausência de exposição à radiação, há necessidade de se realizarem estudos clínicos controlados no ambiente clínico, que avaliem outros desfechos, como o tempo de cirurgia e de sangramento. Nível de evidência IV.

3.
Coluna/Columna ; 12(1): 21-24, 2013. ilus, tab
Artigo em Português | LILACS | ID: lil-673284

RESUMO

OBJETIVO: Analisar experimentalmente a influência do macheamento do orifício piloto nas propriedades mecânicas e na interface osso-implante do parafuso cervical anterior. MÉTODOS: Oito carneiros da raça Santa Inês deslanados foram utilizados no estudo. Nos segmentos vertebrais cervicais de C2-C7 foram realizados orifícios piloto de 2,5mm, de ambos os lados da vértebra. No lado direto da vértebra foi realizado o macheamento previamente a inserção do parafuso cortical de 3,5mm, e no lado esquerdo o implante foi colocado sem o macheamento do orifício piloto. Foram realizados ensaios mecânicos para avaliar a força de arrancamento dos implantes e estudo histomorfométrico da interface osso-implante na fase aguda e oito semanas após a colocação dos implantes. O torque de inserção foi mensurado durante a colocação dos implantes. RESULTADOS: O torque de inserção e a resistência ao arrancamento dos implantes foram maiores nos implantes colocados sem o macheamento do orifício piloto. A interface osso-implante apresentou maior área de contato ósseo e maior área óssea no interior da rosca do implante nos parafusos implantados sem o macheamento prévio. Não foi observado diferença na área óssea fora do passo de rosca do implante. CONCLUSÕES: O macheamento do orifício piloto reduz o torque de inserção e a resistência ao arrancamento do implante na fase aguda e crônica, e reduz a área de contato osso-implante e área de osso no interior do passo de rosca.


OBJECTIVE: Experimentally analyze the influence of the pilot hole tapping on the mechanical properties and the bone-implant interface of anterior cervical screw. METHODS: Eight shorn Santa Inês sheep were used in the study. In cervical segments C2-C7 of the column 2.5mm pilot holes were made on both sides of the vertebra. On the right side of the vertebra tapping was done before the insertion of the cortical screw of 3.5mm, and on the left side the implant was placed without tapping the pilot hole. Mechanical assays were performed to assess the strength of pullout as well as a histomorphometric study of bone-implant interface during the acute phase and eight weeks after implant placement. The insertion torque was measured during implant placement. RESULTS: The insertion torque and pullout strength were higher for implants placed without tapping the pilot hole. The bone-implant interface showed greater area of bone contact and greater bone area within the implant thread on the screws implanted without prior tapping. No differences were observed in the bone outside the thread pitch of the implant. CONCLUSIONS: Tapping the pilot hole reduces insertion torque and pullout strength of the implant in both acute and chronic phases, and reduces the area of bone-implant contact and the bone area within the thread pitch.


OBJETIVO: Para estudiar experimentalmente la influencia del taladramiento del agujero piloto sobre las propiedades mecánicas y la interfaz hueso-implante del tornillo cervical anterior. MÉTODOS: Ocho ovejas Santa Ines fueron utilizadas en el estudio. En los segmentos vertebrales cervicales C2-C7 se hicieron agujeros pilotos de 2,5 mm en ambos lados de la vértebra. En el lado derecho de la vértebra el taladramiento se hizo antes de la inserción del tornillo cortical de 3,5 mm, y en el lado izquierdo el implante fue colocado sin el taladramiento del agujero piloto. Se realizaron ensayos mecánicos para evaluar la fuerza de retirada y el estudio histomorfométrico de la interfase hueso-implante en la fase aguda y ocho semanas después de la colocación del implante. El torque de inserción se midió durante la colocación del implante. RESULTADOS: La fuerza de torsión de la inserción y la resistencia a la extracción fueron más altas en los implantes colocados sin el taladramiento del agujero piloto. La interfaz hueso-implante presentó mayor área de contacto con el hueso y mayor área de hueso dentro de la rosca del implante en los tornillos implantados sin taladramiento previo. No se observaron diferencias en el hueso fuera del paso de la rosca del implante. CONCLUSIONES: El taladramiento del agujero piloto reduce el par de torsión de inserción y la resistencia a la extracción del implante en las fases aguda y crónica, y reduce el área de contacto hueso-implante y el área ósea en el interior del paso de la rosca.


Assuntos
Animais , Fraturas da Coluna Vertebral , Parafusos Ósseos , Fixação de Fratura , Histologia
4.
Rev. bras. ortop ; 46(2): 211-214, maio-abr. 2011. ilus
Artigo em Português | LILACS | ID: lil-592216

RESUMO

Os autores relatam a ocorrência de lesão oculta da articulação manúbrio-esternal na avaliação inicial de um paciente com fratura da coluna torácica (T9). Foi diagnosticada fratura de T9 no paciente do sexo masculino de 37 anos de idade associada a déficit neurológico parcial. No atendimento inicial, as radiografias realizadas não demonstraram a lesão da articulação manúbrioesternal. Durante a reabilitação, após a estabilização cirúrgica da fratura da coluna torácica, subitamente o paciente sentiu dor intensa, acompanhada de deformidade ao nível do esterno, tendo sido diagnosticada luxação manúbrio-esternal nos exames de imagem. Devido à recidiva da luxação e de dor incapacitante, foi necessária a realização da redução aberta e fixação da articulação manúbrio-esternal. Na avaliação após 12 meses, o paciente apresentou recuperação completa da lesão neurológica, consolidação da artrodese do segmento vertebral T7-T11, e manutenção da redução da articulação manúbrio-esternal, que era assintomática durante a realização das atividades cotidianas.


The authors report the occurrence of an occult manubriosternal joint injury in the initial evaluation on a patient with a thoracic spine fracture (T9). This T9 fracture was diagnosed in a 37-year-old man and was associated with a partial neurological deficit. At the initial evaluation, the radiographs produced did not show the manubriosternal joint injury. During rehabilitation, after surgical stabilization of the thoracic spine fracture, the patient suddenly felt an intense pain accompanied by deformation at the sternal level. From imaging examinations, manubriosternal dislocation was diagnosed. Because of recurrence of the dislocation and the incapacitating pain, open reduction and fixation of the manubriosternal joint had to be performed. At the 12-month follow-up, the patient presented complete recovery of the neurological lesion, consolidation of the arthrodesis on the T7-T11 vertebral segment and maintenance of the reduction of the manubriosternal joint, which was asymptomatic during daily activities.


Assuntos
Humanos , Masculino , Adulto , Manúbrio , Coluna Vertebral , Esterno
5.
Coluna/Columna ; 9(3): 258-264, jul.-set. 2010. ilus, graf, tab
Artigo em Português | LILACS | ID: lil-570577

RESUMO

OBJETIVOS: avaliar o resultado do tratamento cirúrgico das deformidades acentuadas da coluna vertebral por meio da utilização da tração halo-gravitacional. MÉTODOS: foram estudados 17 pacientes portadores de diferentes patologias (6 congênitas, 2 pós-neoplasia, 2 neurofibromatoses, 1 idiopática, 1 raquitismo e 5 neuromusculares) submetidos a cirurgia para correção de deformidade de alto valor angular na coluna vertebral. A idade no momento da cirurgia variou de 6 a 26 anos (média de 13,75 anos±4,5). Os parâmetros clínicos avaliados foram o sexo, a idade, o tempo e o peso da tração. Os parâmetros radiográficos estudados foram: a medida da escoliose, da cifose e a altura da coluna vertebral. Os parâmetros radiográficos foram avaliados no período pré-operatório, durante a tração, e no pós-operatório. RESULTADOS: o tempo de tração variou de 14 a 106 dias (34,5±20,83) e a porcentagem de peso da tração em relação ao peso corporal variou de 12,5 a 50 por cento (30 por cento±9,36). A média inicial das escolioses foi de 98,6±25,7º(medida Cobb), reduzido para 83,5º±28,5º durante a tração e para 77º±29,4º no pós-operatório, com a média de correção de 27º, sendo 63 por cento destes ocorridos no período do uso do halo. A média inicial da cifose foi de 86,3±32,08º (Cobb), reduzido para 62,2º±19,9º durante a tração e para 60º±20,9º no pós-operatório, com a média de correção de 26º, sendo 92 por cento durante a tração. CONCLUSÃO: o tratamento cirúrgico das deformidades acentuadas da coluna vertebral, por meio da tração halo-gravitacional pré-operatória, é um método que melhora o ângulo de Cobb reduzindo a correção aguda intraoperatória assim como seus riscos de lesão neurológica.


OBJECTIVE: evaluate the surgical treatment results of severe spine deformities using the preoperative halo gravity traction. METHODS: seventeen scoliosis patients with different pathologies were evaluated (6 congenital, 2 tumor, 2 neurofibromatosis, 1 idiopathic, 1 rickets, and 5 neuromuscular). Those patients underwent a deformity correction surgery in the spine. The variety of age was 6 to 26 years-old (average of 13.75±4.5). The clinical features evaluated were age, gender, time of traction and weight used on traction. The radiographic data analyzed follows: scoliosis curve kyphosis, and spine height. Those features were evaluated in the preoperative, during traction and postoperative period. RESULTS: the time of traction range was of 14 to 106 days (34.5±20.83) and the weight of traction percentage to the patient's body weight varied of 12.5 to 50 percent (30 percent±9.36). The average value for scoliosis was 98.6±25.7º (Cobb) before the surgery and 77º±29.4º postoperative, showing the correction average of 27º with 63 percent of the correction during the traction time. The kyphosis average was 86.3±32.08º (Cobb) before and 60º±20.9º after surgery, representing the correction of 26º, with 92 percent of the correction in the traction time. CONCLUSION: the surgical treatment of severe spine deformities through the preoperative halo gravity traction brings good correction for the curves, thus reducing the amount of intraoperative correction.


OBJETIVOS: evaluar el resultado del tratamiento quirúrgico en deformidades graves de la columna vertebral con el uso de tracción halo gravitacional. MÉTODOS: fueron estudiados 17 pacientes portadores de diferentes patologías (seis congénitas, dos post neoplasia, dos neurofibromatosis, un idiopático, un raquitismo, cinco neuromusculares) sometidos a cirugía para corrección de deformidades graves de la columna vertebral. La edad en el momento de la cirugía variaba de 6 a 26 años (media de 13,75 años ±4,5). Los parámetros clínicos analizados fueron: sexo, edad, tiempo y peso en la tracción y complicaciones clínicas. Los parámetros radiográficos estudiados fueron: medida de la escoliosis, cifosis, altura de la columna vertebral. Los parámetros radiográficos fueron evaluados en el período preoperatorio y post-operatorio. RESULTADOS: el tiempo de tracción varió de 14 hasta 106 días (34.5±20.83) y el porcentaje de peso de la tracción, en relación al peso corporal, varió del 12,5 hasta el 50 por ciento (30 por ciento±9.36). El valor medio de la escoliosis era de 98.6±25.7º (Cobb) antes de la cirugía y de 77±29.4º en el post-operatorio, con una media de corrección de 25º. El valor medio de la cifosis era de 86.3±32.08º (Cobb) antes de la cirugía y de 60 º±20.9 º en el post-operatorio, con una media de corrección de 26º. CONCLUSIÓN: el tratamiento quirúrgico de las deformidades graves de la columna vertebral, por medio de la tracción halo gravitacional, mostró buena corrección de la deformidad, reduciendo la corrección aguda intraoperatoria.


Assuntos
Humanos , Tratamento Terciário , Encefalopatias , Cifose , Escoliose , Coluna Vertebral , Tração
6.
Rev. bras. ortop ; 45(6): 557-564, 2010. ilus, tab
Artigo em Português | LILACS | ID: lil-574820

RESUMO

OBJETIVO: Estudo retrospectivo comparando resultados da IA e da IP em pacientes operados com o diagnóstico de EIA (tipo 1 de Lenke). MÉTODOS: Os resultados de 24 pacientes com idade de 11 a 18 anos com EIA tipo Lenke I e submetidos a tratamento cirúrgico por meio da abordagem anterior (12 pacientes) ou posterior (12 pacientes) foram comparados. Todos os pacientes foram operados pelo mesmo cirurgião e seguidos por um período mínimo de cinco anos. As variáveis de comparação incluíram: correção sagital e coronal, distância da vértebra apical a linha média, rotação da vértebra apical, número de vértebras instrumentadas e variáveis funcionais por meio do questionário SRS-22. Os dados obtidos foram analisados com a versão 9 do programa SAS. Os dois grupos foram comparados com o teste t de Student com um nível de significância de 5 por cento (0,05). RESULTADOS: A correção da curva no plano frontal no pós-operatório imediato (p = 0,031), tardio (p = 0,043) e também a rotação da vértebra apical no pós-operatório imediato (p = 0,002) e tardio (p = 0,021) no grupo de pacientes submetidos à correção por meio da abordagem anterior. O número de vértebras instrumentadas foi 7,69 ± 1,38 no grupo de pacientes submetidos a IA e 11,38 ± 2,92 na IP (p = 0,021). A avaliação funcional (SRS-22) não demonstrou diferença significativa (p > 0,05) entre os grupos. CONCLUSÃO: O grupo de pacientes submetidos à correção da escoliose por instrumentação anterior apresentou maior correção no plano frontal, maior derrotação da vértebra apical e menor número de vértebras artrodesadas.


OBJECTIVE: To evaluate and compare the results of AI and PI in patients diagnosed with Lenke type I curves who were treated surgically. METHODS: The results of 24 patients aged 11 to 18 years with Lenke type I idiopathic scoliosis who underwent surgery with anterior (12 patients) or posterior (12 patients) instrumentation were compared. All patients were operated by the same surgeon and were followed up for a minimum period of five years. Variables for comparison include: coronal and sagittal correction, distance from apical vertebra to midline, apical vertebral rotation, number of instrumented vertebrae and functional variables by means of the SRS-22 questionnaire. The data obtained were analyzed with the SAS program, version 9. The two groups were compared with a 2-tailed Student's t-test with a level of significance set at 5 percent (0.05). RESULTS: The correction of the curve on the frontal plane was higher at immediate (p=0.031) and late postoperative (p=0.043) as well the apical vertebral rotation during immediate (p=0.002) and late (p=0.019) evaluation in the anterior spinal fusion group. The number of instrumented vertebrae was 7.69±1.38 in the anterior spinal fusion patients and 11.38±2.92 in the posterior spine fusion patients (p=0.021). Functional assessment (SRS-22) showed no significant difference (p>0.05) between groups. CONCLUSION: Anterior spine fusion patients presented greater scoliosis correction on frontal plane, greater derotation of apical vertebrae and smaller number of fused vertebrae.


Assuntos
Humanos , Masculino , Feminino , Adolescente , Coluna Vertebral/anormalidades , Coluna Vertebral , Escoliose , Instrumentos Cirúrgicos
7.
Rev. bras. ortop ; 44(1): 20-25, jan.-fev. 2009. ilus, graf, tab
Artigo em Português | LILACS | ID: lil-572654

RESUMO

OBJETIVO: Avaliar por meio de histomorfometria, a espessura da placa vertebral terminal, a espessura do disco intervertebral e a sua correlação nas diferentes faixas etárias, tentando identificar a sua correlação. MÉTODOS: Foram avaliados os segmentos cervicais C4-C5 e C5-C6 de 50 cadáveres humanos , de ambos os sexos, divididos em 5 grupos com intervalo de faixa etária de 10 anos, a partir dos 21 anos de idade. A avaliação da espessura da PVT e do disco intervertebral foi realizada por meio de avaliação histomorfométrica dos cortes histológicos corados pela hematoxilina e eosina. A espessura da PVT inferior de C4, PVT superior de C5, PVT inferior de C5 e PVT superior de C6 foram comparadas entre si e também com a espessura do disco intervertebral interposto entre as respectivas PVT. RESULTADOS: A espessura das placas vertebrais terminais adjacentes ao mesmo DI não apresentou diferença estatística. No entanto, a comparação da espessura das placas vertebrais superior e inferior da mesma vértebra cervical (C5), apresentou diferença estatística em todas as faixas etárias avaliadas. Foi observado coeficiente de correlação estatística, maior que 80 por cento, entre a espessura daplaca vertebral terminal e o disco intervertebral adjacente, com proporcional redução de espessura de ambas estruturas, nos diferentes níveis cervicais avaliados, e também nas diferentes faixas etárias avaliadas. CONCLUSÃO: A placa vertebral terminal apresenta correlação morfológica com o disco intervertebral ao qual entra em contato, e não apresenta correlação com a placa vertebral terminal da mesma vértebra.


OBJECTIVE: To evaluate, by means of histomorphometry, terminal vertebral plate thickness, intervertebral disc thickness and its correlation on different age groups, seeking to identify its correlation. METHODS: C4-C5 and C5-C6 cervical segments removed from human cadavers of both genders were assessed and divided into five groups of 10-year age intervals, from 21 years old. TVP and intervertebral disc thickness evaluation was made by means of histomorphometry of histological slides stained with hematoxylin and eosyn. Lower C4 TVP, upper C5 TVP, and upper C6 TVP de were compared between each other and to the interposed intervertebral disc thickness between relevant TVP. RESULTS: The thickness of terminal vertebral plates adjacent to the same ID did not show statistic differences. However, the comparison of upper and lower vertebral plates thickness on the same cervical vertebra (C5), showed statistical difference on all age groups studied. We found a statistical correlation coefficient above 80 percent between terminal vertebral plate and adjacent intervertebral disc, witha proportional thickness reduction of both structures on the different cervical levels studied, and also on the different age groups assessed. CONCLUSION: Terminal vertebral plate shows a morphologic correlation with the intervertebral disc next to it, and does not show correlation with the terminal vertebral plate on the same vertebra.


Assuntos
Cadáver , Disco Intervertebral , Coluna Vertebral
8.
Rev. bras. ortop ; 44(6): 513-517, 2009. ilus, tab
Artigo em Português | LILACS | ID: lil-538068

RESUMO

OBJETIVO: Avaliar o resultado do tratamento cirúrgico da hipercifose dorsal da coluna vertebral por meio da técnica de Ponte (osteotomias múltiplas posteriores). MÉTODOS: Estudo retrospectivo de 10 pacientes (oito com sequela de doença de Scheuermann e dois com sequela de laminectomia) submetidos a cirurgia para correção de hipercifose acima de 70º. A idade variou de 12 anos a 20 anos (média de 16,8 anos ± 2,89). Os parâmetros radiográficos estudados foram a mensuração da cifose, lordose e, quando presente, da escoliose. Também foram avaliadas a presença de cifose juncional proximal e distal, a perda da correção e complicações como soltura e quebra dos implantes. Os parâmetros radiográficos foram avaliados no período pré-operatório, pós-operatório imediato e avaliação tardia. RESULTADOS: Os pacientes foram seguidos por um período que variou de 24 a 144 meses (média de 65,8 meses ± 39,92). O valor médio da hipercifose pré-operatória foi de 78,8º ± 7,59º (Cobb) e de 47,5º ± 12,54º no seguimento, com a média de correção de 33,9º ± 9,53º e perda média de correção de 2,2º. CONCLUSÃO: O tratamento cirúrgico da hipercifose torácica por meio de osteotomias múltiplas posteriores apresentou boa correção da deformidade e perda mínima de correção ao longo do seguimento.


OBJECTIVE: To evaluate the results of the surgical treatment of the spinal Kyphosis using the Ponte's technique (multiple posterior osteotomies). METHODS: Ten patients (8 with Scheuermannïs kyphosis and 2 with kyphosis after laminectomy) submitted to surgical correction of kyphotic deformity greater than 70º were retrospectively assessed. The age at the surgical time ranged from 12 to 20 years old (mean age16.8 years ± 2.89). The radiographic parameters evaluated were the kyphosis, the lordosis and the scoliosis - whenever present. The presence of proximal and distal junctional kyphosis, loss of correction, and complications as implants loosening and breakage were also assessed. The radiographic parameters were evaluated at the preoperative, early postoperative and late postoperative time. RESULTS: The patients were followed through a period that ranged from 24 to 144 months (65.8 ±39.92). The mean value of the kyphosis was 78.8º ± 7.59º (Cobb) before surgery and 47.5º ± 12.54º at late follow up, with mean correction of 33.9º ± 9.53º and lost correction of 2.2º. CONCLUSION: The surgical treatment of the thoracic kyphosis using multiples posterior osteotomies presented a good correction of the deformity and minimal lost of correction during follow up.


Assuntos
Humanos , Masculino , Feminino , Adolescente , Adulto , Coluna Vertebral/patologia , Cifose , Osteotomia , Doença de Scheuermann , Fusão Vertebral
9.
Rev. bras. ortop ; 43(5): 203-208, maio 2008. ilus
Artigo em Português | LILACS | ID: lil-484964

RESUMO

A luxação traumática atlanto-occipital é lesão rara, de incidência desconhecida e está associada a elevada taxa de mortalidade. Os autores relatam o diagnóstico, tratamento e seguimento de dois anos de uma paciente de 25 anos de idade, vítima de acidente automobilístico e luxação atlanto-occipital traumática confirmada por exames de imagem.


Traumatic atlanto-occipital dislocation is a rare lesion whose incidence is not know, and which is associated to a high rate of mortality. The authors report the diagnosis, treatment, and two-year follow-up of a 25 year-old patient who had had an automobile accident with imaging-confirmed traumatic atlanto-occipital dislocation.


Assuntos
Humanos , Feminino , Adulto , Articulação Atlantoccipital , Traumatismos da Coluna Vertebral/cirurgia , Traumatismos da Coluna Vertebral/diagnóstico
10.
Acta ortop. bras ; 13(3): 137-140, 2005. tab, graf
Artigo em Português | LILACS | ID: lil-410761

RESUMO

O objetivo desse estudo é descrever o perfil sócio-demográfico de pacientes vítimas de trauma atendidos em um hospital de referência da rede pública de Fortaleza - Brasil. Também pretende relacionar o tempo de espera para o atendimento com a satisfação pessoal do paciente em relação ao serviço prestado. Outro ponto abordado nesse estudo é a análise das patologias músculo-esqueléticas mais freqüentes nessa população. Foi realizado um estudo transversal durante os anos de 2002 e 2003 em hospital de referência em trauma da rede pública da cidade de Fortaleza - Brasil. Foram incluídos no estudo 500 pacientes atendidos na emergência. Após a realização da análise desse estudo, podemos idealizar um perfil do paciente atendido na rede pública de saúde vítima de trauma músculo-esquelético em Fortaleza: Paciente do sexo masculino (60,7 por cento), cor parda (55 por cento), jovem entre quinze e trinta anos (55 por cento), procedente de Fortaleza (74 por cento), proveniente de família com renda inferior a dois salários mínimos (60 por cento) e relativamente hígido, sendo as fraturas o principal tipo de lesão (48 por cento). Pacientes atendidos em hospitais de referência em trauma constituem um problema social importante e, na maioria dos casos, apresentam lesões graves, o que demonstra a necessidade e importância de investimentos nesse setor.


Assuntos
Humanos , Pré-Escolar , Criança , Adolescente , Adulto , Pessoa de Meia-Idade , Serviço Hospitalar de Emergência , Fraturas Ósseas , Ferimentos e Lesões/epidemiologia , Fraturas Ósseas/epidemiologia , Fraturas Ósseas/etnologia , Brasil/epidemiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA